According to a report by the washing state university extension energy program blown in fiberglass insulation provides an r value of between 2 2 and 2 7 per inch.
R value for attic knee wall.
Insulating the roof rather than knee walls and attic s floor while usually preferable is not a great option for this house for a number of reasons specific to this house.
With 2 layers between the joists and another layer running perpendicular over top the r value of the insulation in the side attic is in the range of r 40.
This adds an additional r19 to the wall insulates all the studs to stop any thermal bridging and provides an airtight assembly.
The recommended r value for attic floor insulation for this house is r 38.
The homeowner could then check table 1 to find several choices.
Most computer programs allow the user to calculate gross wall areas and subtract window and door areas.
2 4 insulation has an r value of 13 5.
Superb thermo insulating parameters r value 5 2 along with high air tightness keep heat loss to a minimum.
0 19 btu hft f loft ladder hatch u value 1 1 8 insulation thickness 5 2 attic ladder r value the knee wall access door dwk is intended to be built into l shaped walls.
R values of framing members concrete blocks gypsum board etc.
This knee wall has been encapsulated with 2 part closed cell spray foam.
A 2 x 4 wall cavity with blown in fiberglass insulation will provide on average an r 13 to r 15 insulation value.
Also to find out where your home might be losing energy consider conducting an energy audit.
If the existing attic floor insulation has an r 11 insulation value then an additional r 27 would be needed to bring the attic floor insulation up to the level recommended for that house.
Walls are entered by the type of assembly and the r value of insulation.
So for instance i believe in my area zone 4 code would state you should r20 for walls and r49 for ceilings what would you believe the r value should be for knee walls using an insulation goal comparable to the goal the code sought.
As far as making the knee walls conditioned space as long as you get ventilation and adequate r value of at least r 49 i say go for it.
We did it in one house but the customer was not as satisfied as i would like of course she was a little tougher than most customers.
By adding an r19 to the existing r13 cavity insulation the knee wall assembly total r value is near r30 and is air tight.
1 use an r value map to determine the amount of insulation you need.
A well insulated side attic.